{"id":121,"date":"2023-08-14T15:30:02","date_gmt":"2023-08-14T19:30:02","guid":{"rendered":"https:\/\/water.phila.gov\/design\/?page_id=121"},"modified":"2026-03-10T00:44:31","modified_gmt":"2026-03-10T04:44:31","slug":"appendices","status":"publish","type":"page","link":"https:\/\/water.phila.gov\/design\/manual\/appendices\/","title":{"rendered":"Appendices"},"content":{"rendered":"\n<div class=\"wp-block-buttons mt2 is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-large\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendices.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Download All Appendices<\/a><\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading no-break-before\" id=\"i\"><a rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-i-procedures.pdf\" target=\"_blank\">Appendix I: Procedures<\/a><\/h3>\n\n\n\n<h6 class=\"wp-block-heading mb0 has-med-gray-color has-text-color\">Table of Contents<\/h6>\n\n\n\n<ul class=\"wp-block-list noicons\">\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-i-procedures.pdf#page=2\" target=\"_blank\">a \u2013 Water and Sewer Project Flow Chart<\/a><\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-i-procedures.pdf#page=3\" target=\"_blank\">b \u2013 Guidelines for Preparing Amendments<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ii\"><a rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf\" target=\"_blank\">Appendix II: Drawing Standards<\/a><\/h3>\n\n\n\n<h6 class=\"wp-block-heading mb0 has-med-gray-color has-text-color\">Table of Contents<\/h6>\n\n\n\n<ul class=\"wp-block-list noicons\">\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=2\" target=\"_blank\" rel=\"noreferrer noopener\">a \u2013 Drawing Size and Borders (Water)<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=3\" target=\"_blank\" rel=\"noreferrer noopener\">b \u2013 Drawing Size and Borders (Sewer)<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=4\" target=\"_blank\" rel=\"noreferrer noopener\">c \u2013 Title Block (Water Drawing)<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=5\" target=\"_blank\" rel=\"noreferrer noopener\">d \u2013 Title Block (Sewer Drawing)<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=6\" target=\"_blank\" rel=\"noreferrer noopener\">e \u2013 Line Styles<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=7\" target=\"_blank\" rel=\"noreferrer noopener\">f \u2013 Lettering<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=8\" target=\"_blank\" rel=\"noreferrer noopener\">g \u2013 Arrow Symbols<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=9\" target=\"_blank\" rel=\"noreferrer noopener\">h \u2013 Symbols for Water Main Fittings<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=11\" target=\"_blank\" rel=\"noreferrer noopener\">i \u2013 Standard Notes for Water Sheets<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=12\" target=\"_blank\" rel=\"noreferrer noopener\">j \u2013 Legend for Sewer Sheets<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=13\" target=\"_blank\" rel=\"noreferrer noopener\">k \u2013 Manholes, Inlets, and Appurtenances<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=14\" target=\"_blank\" rel=\"noreferrer noopener\">m \u2013 Standard Notes for Sewer Sheets<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ii-drawing-standards.pdf#page=15\" target=\"_blank\" rel=\"noreferrer noopener\">n \u2013 Symbols for Green Appurtenances<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"iii\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-iii-forms-and-calculations.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Appendix III: Forms and Calculations<\/a><\/h3>\n\n\n\n<h6 class=\"wp-block-heading mb0 has-med-gray-color has-text-color\">Fillable Template File<\/h6>\n\n\n<div id=\"doctable-block_c872f0e9102a6aa9b8870033f8561eee\" class=\"wp-block-ls-doctable doctable mt0 nosearch\">\n\t<table class=\"docblock\" data-toggle=\"table\" searchable\" data-search=\"true\" data-trim-on-search=\"false\" data-pagination=\"true\" data-show-extended-pagination=\"true\" data-page-size=\"10\" data-pagination-loop=\"false\" data-page-list=\"\">\t\t<thead>\n\t\t\t<tr><th class=\"title-link\" data-field=\"title\" data-sortable=\"true\">File<\/th><th data-field=\"filetype\" class=\"file type\" data-sortable=\"true\">File Type<\/th><th data-field=\"filesize\" class=\"file size\" data-sortable=\"true\" data-sort-name=\"bytes\">File Size<\/th><th data-field=\"bytes\" data-visible=\"false\" class=\"bytes\">Bytes<\/th><\/tr>\n\t\t<\/thead>\n\t\t<tbody><tr id=\"doctable-block_c872f0e9102a6aa9b8870033f8561eee-resource-0\" class=\"clickable-row\" data-href=\"https:\/\/phila.sharepoint.com\/:x:\/r\/sites\/waterengdocsext\/References\/WaterSewer\/QuantityCalculations\/WaterSewer_Quantities.xlsm?d=w4fb86f8eaf8c4acd9d9790198c7dfa5a&#038;csf=1&#038;web=1&#038;e=OxhXEi\"><td class=\"title-link\" data-label=\"File\"><a title=\"a \u2013 Water\/Sewer Quantities Sheet Template\" href=\"https:\/\/phila.sharepoint.com\/:x:\/r\/sites\/waterengdocsext\/References\/WaterSewer\/QuantityCalculations\/WaterSewer_Quantities.xlsm?d=w4fb86f8eaf8c4acd9d9790198c7dfa5a&#038;csf=1&#038;web=1&#038;e=OxhXEi\" target=\"_blank\">a \u2013 Water\/Sewer Quantities Sheet Template<\/a><\/td><td class=\"file type\" data-label=\"File Type\">xlsm<\/td><td class=\"file size\" data-label=\"File Size\" data-order=\"\">&mdash;<\/td><td class=\"bytes\"><\/td><\/tr><tr id=\"doctable-block_c872f0e9102a6aa9b8870033f8561eee-resource-1\" class=\"clickable-row\" data-href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/iiif-final-design-package-checklist.docx\"><td class=\"title-link\" data-label=\"File\"><a title=\"b \u2013 Final Design Package Checklist\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/iiif-final-design-package-checklist.docx\" target=\"_blank\">b \u2013 Final Design Package Checklist<\/a><\/td><td class=\"file type\" data-label=\"File Type\">docx<\/td><td class=\"file size\" data-label=\"File Size\" data-order=\"45731\">44.66 KB<\/td><td class=\"bytes\">45731<\/td><\/tr><tr id=\"doctable-block_c872f0e9102a6aa9b8870033f8561eee-resource-2\" class=\"clickable-row\" data-href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/iiig-contract-summary-sheet.xls\"><td class=\"title-link\" data-label=\"File\"><a title=\"c \u2013 Contract Summary Sheet\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/iiig-contract-summary-sheet.xls\" target=\"_blank\">c \u2013 Contract Summary Sheet<\/a><\/td><td class=\"file type\" data-label=\"File Type\">xls<\/td><td class=\"file size\" data-label=\"File Size\" data-order=\"28160\">27.50 KB<\/td><td class=\"bytes\">28160<\/td><\/tr><tr id=\"doctable-block_c872f0e9102a6aa9b8870033f8561eee-resource-3\" class=\"clickable-row\" data-href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/oeo-post-award-compliance-form.pdf\"><td class=\"title-link\" data-label=\"File\"><a title=\"d \u2013 OEO post Award Compliance Form\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/oeo-post-award-compliance-form.pdf\" target=\"_blank\">d \u2013 OEO post Award Compliance Form<\/a><\/td><td class=\"file type\" data-label=\"File Type\">pdf<\/td><td class=\"file size\" data-label=\"File Size\" data-order=\"283480\">276.84 KB<\/td><td class=\"bytes\">283480<\/td><\/tr><tr id=\"doctable-block_c872f0e9102a6aa9b8870033f8561eee-resource-4\" class=\"clickable-row\" data-href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/iiii-project-status-summary-sheet.xls\"><td class=\"title-link\" data-label=\"File\"><a title=\"e \u2013 Project Status Summary Sheet\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/iiii-project-status-summary-sheet.xls\" target=\"_blank\">e \u2013 Project Status Summary Sheet<\/a><\/td><td class=\"file type\" data-label=\"File Type\">xls<\/td><td class=\"file size\" data-label=\"File Size\" data-order=\"29696\">29.00 KB<\/td><td class=\"bytes\">29696<\/td><\/tr><tr id=\"doctable-block_c872f0e9102a6aa9b8870033f8561eee-resource-5\" class=\"clickable-row\" data-href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/iiij-independent-quantity-verification-form.pdf\"><td class=\"title-link\" data-label=\"File\"><a title=\"f \u2013 Independent Quantity Verification Form\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/iiij-independent-quantity-verification-form.pdf\" target=\"_blank\">f \u2013 Independent Quantity Verification Form<\/a><\/td><td class=\"file type\" data-label=\"File Type\">pdf<\/td><td class=\"file size\" data-label=\"File Size\" data-order=\"9980\">9.75 KB<\/td><td class=\"bytes\">9980<\/td><\/tr><\/tbody>\n\t<\/table>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"iv\"><a rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-iv-external-organizations-requirements.pdf\" target=\"_blank\">Appendix IV: External Organization\u2019s Requirements<\/a><\/h3>\n\n\n\n<h6 class=\"wp-block-heading mb0 has-med-gray-color has-text-color\">Table of Contents<\/h6>\n\n\n\n<ul class=\"wp-block-list noicons\">\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/fire-hydrant-legend-3-29-23.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">a \u2013 Legend for Fire Dept. Review of Hydrant Locations<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-iv-external-organizations-requirements.pdf#page=3\" target=\"_blank\" rel=\"noreferrer noopener\">b \u2013 Highway Opening Permit Application (GPIS)<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-iv-external-organizations-requirements.pdf#page=4\" target=\"_blank\" rel=\"noreferrer noopener\">c \u2013 ADA Handicap Ramp Design Guidance<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-iv-external-organizations-requirements.pdf#page=6\" target=\"_blank\" rel=\"noreferrer noopener\">d \u2013 Highway Opening Guidelines<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-iv-external-organizations-requirements.pdf#page=31\" target=\"_blank\" rel=\"noreferrer noopener\">e \u2013 PennDOT Highway Occupancy Permit<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-iv-external-organizations-requirements.pdf#page=32\" target=\"_blank\" rel=\"noreferrer noopener\">f \u2013 Police Support for Utility Construction<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-iv-external-organizations-requirements.pdf#page=37\" target=\"_blank\" rel=\"noreferrer noopener\">g \u2013 Philadelphia Gas Works (PGW) Agreement<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-iv-external-organizations-requirements.pdf#page=50\" target=\"_blank\" rel=\"noreferrer noopener\">h \u2013 Roadway Grading Plan Procedure<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-iv-external-organizations-requirements.pdf#page=51\" target=\"_blank\" rel=\"noreferrer noopener\">i \u2013 PennDOT Pre-EPS Submittal Form and Instructions<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/20260227-paving-restoration-flowchart.pdf\" data-type=\"link\" data-id=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/20260227-paving-restoration-flowchart.pdf\">j &#8211; City Street Roadway Restoration Flow Chart<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/images\/ppr-permit-guidance.jpg\" data-type=\"link\" data-id=\"https:\/\/water.phila.gov\/wp-content\/uploads\/images\/ppr-permit-guidance.jpg\">k \u2013 PP&amp;R Permit Guidance<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/2025-ppr-insurancerequirementslanguagerequirements-merged-1.pdf\" data-type=\"link\" data-id=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/2025-ppr-insurancerequirementslanguagerequirements-merged-1.pdf\">l \u2013 PP&amp;R Permittee Insurance Requirements<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/2025-parksrec-general-boringexcavation-application-1.xlsx\" data-type=\"link\" data-id=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/2025-parksrec-general-boringexcavation-application-1.xlsx\">m \u2013 PP&amp;R Application for Permit<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/2025-ppr-parkpermittreeremovalrequirements.pdf\">n \u2013 PP&amp;R Tree Removal Requirements<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"v\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-v-reference-plans-and-information.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Appendix V: Reference Plans and Information<\/a><\/h3>\n\n\n\n<h6 class=\"wp-block-heading mb0 has-med-gray-color has-text-color\">Table of Contents<\/h6>\n\n\n\n<ul class=\"wp-block-list noicons\">\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-v-reference-plans-and-information.pdf#page=2\" target=\"_blank\" rel=\"noreferrer noopener\">a \u2013 Preferred Inlet Locations<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-v-reference-plans-and-information.pdf#page=3\" target=\"_blank\" rel=\"noreferrer noopener\">b \u2013 Inlet Pictures<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-v-reference-plans-and-information.pdf#page=22\" target=\"_blank\" rel=\"noreferrer noopener\">c \u2013 Upper End Vent Pipe Picture<\/a><\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-v-reference-plans-and-information.pdf#page=23\" target=\"_blank\">d \u2013 Drainage Plat Map<\/a> (<a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/sewerplat.kml\">kml<\/a>)<\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-v-reference-plans-and-information.pdf#page=24\" target=\"_blank\">e \u2013 Water Plat Map<\/a> (<a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/waterplates.kml\">kml<\/a>)<\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-v-reference-plans-and-information.pdf#page=25\" target=\"_blank\" rel=\"noreferrer noopener\">f \u2013 1907 Standard Details for Sewers<\/a><\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-v-reference-plans-and-information.pdf#page=55\" target=\"_blank\">g \u2013 Streets Department Survey Districts<\/a> (<a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/surveydistricts.kml\">kml<\/a>)<\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-v-reference-plans-and-information.pdf#page=56\" target=\"_blank\">h \u2013 Highway Districts<\/a> (<a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/5hhighwaydistricts.kml\">kml<\/a>)<\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-v-reference-plans-and-information.pdf#page=57\" target=\"_blank\" rel=\"noreferrer noopener\">i \u2013 State Highway Route Numbers (List)<\/a><\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-v-reference-plans-and-information.pdf#page=63\" target=\"_blank\">j \u2013 State Highway Route Numbers (Map)<\/a> (<a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/statehighways.kml\">kml<\/a>)<\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-v-reference-plans-and-information.pdf#page=64\" target=\"_blank\">k \u2013 Wards<\/a> (<a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/wards.kml\">kml<\/a>)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vi\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-vi-contact-information.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Appendix VI: Contact Information<\/a><\/h3>\n\n\n\n<h6 class=\"wp-block-heading mb0 has-med-gray-color has-text-color\">Table of Contents<\/h6>\n\n\n\n<ul class=\"wp-block-list noicons\">\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-vi-contact-information.pdf#page=2\" target=\"_blank\" rel=\"noreferrer noopener\">a \u2013 PWD Contact Information<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-vi-contact-information.pdf#page=4\" target=\"_blank\" rel=\"noreferrer noopener\">b \u2013 District Surveyor Contact Information<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vii\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-vii-di-fittings.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Appendix VII: D.I. Fittings<\/a><\/h3>\n\n\n\n<h6 class=\"wp-block-heading mb0 has-med-gray-color has-text-color\">Table of Contents<\/h6>\n\n\n\n<ul class=\"wp-block-list noicons\">\n<li>a \u2013 Weight of Ductile Iron Fittings\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-vii-di-fittings.pdf#page=2\" target=\"_blank\" rel=\"noreferrer noopener\">Crosses<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-vii-di-fittings.pdf#page=5\" target=\"_blank\" rel=\"noreferrer noopener\">Tees<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-vii-di-fittings.pdf#page=10\" target=\"_blank\" rel=\"noreferrer noopener\">Bends<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-vii-di-fittings.pdf#page=14\" target=\"_blank\" rel=\"noreferrer noopener\">Offsets<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-vii-di-fittings.pdf#page=15\" target=\"_blank\" rel=\"noreferrer noopener\">Reducers<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-vii-di-fittings.pdf#page=18\" target=\"_blank\" rel=\"noreferrer noopener\">Sleeves<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-vii-di-fittings.pdf#page=20\" target=\"_blank\" rel=\"noreferrer noopener\">Caps and Plugs<\/a><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"viii\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Appendix VIII: Flows &amp; Velocities<\/a><\/h3>\n\n\n\n<h6 class=\"wp-block-heading mb0 has-med-gray-color has-text-color\">Table of Contents<\/h6>\n\n\n\n<ul class=\"wp-block-list noicons\">\n<li>a \u2013 Velocities &amp; Flow Capacities for Pipe Sewers\n<ul class=\"wp-block-list columns-2\">\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=2\" target=\"_blank\" rel=\"noreferrer noopener\">10\u201d VC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=3\" target=\"_blank\" rel=\"noreferrer noopener\">12\u201d VC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=4\" target=\"_blank\" rel=\"noreferrer noopener\">15\u201d VC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=5\" target=\"_blank\" rel=\"noreferrer noopener\">18\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=6\" target=\"_blank\" rel=\"noreferrer noopener\">21\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=7\" target=\"_blank\" rel=\"noreferrer noopener\">24\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=8\" target=\"_blank\" rel=\"noreferrer noopener\">27\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=9\" target=\"_blank\" rel=\"noreferrer noopener\">30\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=10\" target=\"_blank\" rel=\"noreferrer noopener\">36\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=11\" target=\"_blank\" rel=\"noreferrer noopener\">42\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=12\" target=\"_blank\" rel=\"noreferrer noopener\">48\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=13\" target=\"_blank\" rel=\"noreferrer noopener\">54\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=14\" target=\"_blank\" rel=\"noreferrer noopener\">60\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=15\" target=\"_blank\" rel=\"noreferrer noopener\">66\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=16\" target=\"_blank\" rel=\"noreferrer noopener\">72\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=17\" target=\"_blank\" rel=\"noreferrer noopener\">78\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=18\" target=\"_blank\" rel=\"noreferrer noopener\">84\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=19\" target=\"_blank\" rel=\"noreferrer noopener\">90\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=20\" target=\"_blank\" rel=\"noreferrer noopener\">96\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=21\" target=\"_blank\" rel=\"noreferrer noopener\">102\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=22\" target=\"_blank\" rel=\"noreferrer noopener\">108\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=23\" target=\"_blank\" rel=\"noreferrer noopener\">114\u201d RC Pipe<\/a><\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-viii-flows-and-velocities.pdf#page=24\" target=\"_blank\">120\u201d RC Pipe<\/a><br>&nbsp;<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ix\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ix-sample-plans.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Appendix IX: Sample Plans<\/a><\/h3>\n\n\n\n<h6 class=\"wp-block-heading mb0 has-med-gray-color has-text-color\">Table of Contents<\/h6>\n\n\n\n<ul class=\"wp-block-list noicons\">\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ix-sample-plans.pdf#page=2\" target=\"_blank\" rel=\"noreferrer noopener\">a \u2013 Sample Water Drawing<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ix-sample-plans.pdf#page=3\" target=\"_blank\" rel=\"noreferrer noopener\">b \u2013 Sample Combined Sewer Drawing (S-1)<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ix-sample-plans.pdf#page=4\" target=\"_blank\" rel=\"noreferrer noopener\">c \u2013 Sample Sewer Match Line Drawing (S-3)<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ix-sample-plans.pdf#page=5\" target=\"_blank\" rel=\"noreferrer noopener\">d \u2013 Sample Separate Sewer Drawing<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-ws-design-manual-appendix-ix-sample-plans.pdf#page=6\" target=\"_blank\" rel=\"noreferrer noopener\">e \u2013 Sample Roadway Grading Drawing<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Appendix I: Procedures Table of Contents Appendix II: Drawing Standards Table of Contents Appendix III: Forms and Calculations Fillable Template File Appendix IV: External Organization\u2019s Requirements Table of Contents Appendix V: Reference Plans and Information Table of Contents Appendix VI: Contact Information Table of Contents Appendix VII: D.I. Fittings Table of Contents Appendix VIII: Flows [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":2,"menu_order":10,"comment_status":"closed","ping_status":"closed","template":"page-manual.php","meta":{"custom_css":"#print-download { display: none; }\r\n.page-content ul { margin-top: 0 !important; }\r\n.nosearch .search { display: none; }\r\nul.columns-2 { columns: 2; margin-top: .5em !important; }\r\nul.columns-2 li:first-child { margin-top: 0; }","custom_js":"","noindex":"","version":"4.1","effective":"","short-page-title":""},"section":[],"class_list":["post-121","page","type-page","status-publish","hentry","wpautop"],"acf":[],"parsely":{"version":"1.1.0","canonical_url":"https:\/\/phila.gov\/design\/manual\/appendices\/","smart_links":{"inbound":0,"outbound":0},"traffic_boost_suggestions_count":0,"meta":{"@context":"https:\/\/schema.org","@type":"WebPage","headline":"Appendices","url":"http:\/\/water.phila.gov\/design\/manual\/appendices\/","mainEntityOfPage":{"@type":"WebPage","@id":"http:\/\/water.phila.gov\/design\/manual\/appendices\/"},"thumbnailUrl":"","image":{"@type":"ImageObject","url":""},"articleSection":"Uncategorized","author":[{"@type":"Person","name":"Lauren Sell"}],"creator":["Lauren Sell"],"publisher":{"@type":"Organization","name":"Water &amp; Sewer Design","logo":""},"keywords":[],"dateCreated":"2023-08-14T19:30:02Z","datePublished":"2023-08-14T19:30:02Z","dateModified":"2026-03-10T04:44:31Z"},"rendered":"<script type=\"application\/ld+json\" class=\"wp-parsely-metadata\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@type\":\"WebPage\",\"headline\":\"Appendices\",\"url\":\"http:\\\/\\\/water.phila.gov\\\/design\\\/manual\\\/appendices\\\/\",\"mainEntityOfPage\":{\"@type\":\"WebPage\",\"@id\":\"http:\\\/\\\/water.phila.gov\\\/design\\\/manual\\\/appendices\\\/\"},\"thumbnailUrl\":\"\",\"image\":{\"@type\":\"ImageObject\",\"url\":\"\"},\"articleSection\":\"Uncategorized\",\"author\":[{\"@type\":\"Person\",\"name\":\"Lauren Sell\"}],\"creator\":[\"Lauren Sell\"],\"publisher\":{\"@type\":\"Organization\",\"name\":\"Water &amp; Sewer Design\",\"logo\":\"\"},\"keywords\":[],\"dateCreated\":\"2023-08-14T19:30:02Z\",\"datePublished\":\"2023-08-14T19:30:02Z\",\"dateModified\":\"2026-03-10T04:44:31Z\"}<\/script>","tracker_url":"https:\/\/cdn.parsely.com\/keys\/phila.gov\/p.js"},"_links":{"self":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages\/121","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/comments?post=121"}],"version-history":[{"count":19,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages\/121\/revisions"}],"predecessor-version":[{"id":1084,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages\/121\/revisions\/1084"}],"up":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages\/2"}],"wp:attachment":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/media?parent=121"}],"wp:term":[{"taxonomy":"section","embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/section?post=121"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}