{"id":16,"date":"2021-05-07T15:11:44","date_gmt":"2021-05-07T19:11:44","guid":{"rendered":"https:\/\/water.phila.gov\/design\/?page_id=16"},"modified":"2022-11-09T12:54:51","modified_gmt":"2022-11-09T17:54:51","slug":"water-standard-details","status":"publish","type":"page","link":"https:\/\/water.phila.gov\/design\/water-standard-details\/","title":{"rendered":"Water Standard Details"},"content":{"rendered":"\n<div class=\"wp-block-columns fa-stretch is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Jump to:<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li><a href=\"#install\">Install<\/a><\/li><li><a href=\"#thrust\">Thrust<\/a><\/li><li><a href=\"#valve\">Valve<\/a><\/li><\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Files:<\/h3>\n\n\n\n<div class=\"wp-block-buttons is-vertical is-layout-flex wp-container-core-buttons-is-layout-8cf370e7 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-100\"><a class=\"wp-block-button__link\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/water-standard-details-2022.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Compiled Water Standard Details List<\/a><\/div>\n\n\n\n<div class=\"wp-block-button has-custom-width wp-block-button__width-100\"><a class=\"wp-block-button__link\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/water-standard-cad-files.zip\">Water Standard CAD Files<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"has-text-align-center mt_5 wp-block-heading\" id=\"table-of-contents\">Table of Contents<\/h3>\n\n\n\n<h4 class=\"has-text-align-center mt0 wp-block-heading\" id=\"install\">Install<\/h4>\n\n\n\n<figure class=\"wp-block-table alignwide mt0\"><table><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Detail ID<\/th><th>Detail Name<\/th><th class=\"has-text-align-center\" data-align=\"center\">CAD File<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/push-on-joint-assembly-detail.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Install-01<\/a><\/td><td><strong>Push on Joint Assembly Detail<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/push-on-joint-assembly-detail.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/mechanical-joint-assembly-detail-wedge-action.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Install-02<\/a><\/td><td><strong>Mechanical Joint Assembly Detail Wedge<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/mechanical-joint-assembly-detail-wedge-action.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pay-limits-for-excavation-of-water-main-trenches.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Install-03<\/a><\/td><td><strong>Pay Limits for Excavation of Water Main Trenches<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pay-limits-for-excavation-of-water-main-trenches.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/excavation-pay-limit-dimensions.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Install-04<\/a><\/td><td><strong>Excavation Pay Limit Dimensions<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/excavation-pay-limit-dimensions.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/trench-resoration-detail-city-streets.pdf\">Install-05<\/a><\/td><td><strong>Trench Restoration Detail \u2013 City Streets<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/trench-restoration-detail-city-streets.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pay-limits-city-streets.pdf\">Install-06<\/a><\/td><td><strong>Paving Dimensions &amp; Quantities \u2013 City Streets<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pay-limits-for-repaving-water-main-trenches.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Install-07<\/td><td><strong>Trench Restoration Detail \u2013 State Routes<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2013<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Install-08<\/td><td><strong>Paving Dimensions &amp; Quantities \u2013 State Routes<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2013<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/exposed-water-main-frost-protective-coating.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Install-09<\/a><\/td><td><strong>Frost Protective Coating<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/exposed-water-main-frost-protective-coating.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/service-connections-2-and-smaller-pg-1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Install-10-A<\/a><\/td><td><strong>Service Connections 2&#8243; and Smaller \u2013 Pg. 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2013<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/service-connections-2-and-smaller-pg-2.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Install-10-B<\/a><\/td><td><strong>Service Connections 2&#8243; and Smaller \u2013 Pg. 2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2013<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/fire-hydrant-installation.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Install-11<\/a><\/td><td><strong>Fire Hydrant Installation<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/fire-hydrant-installation.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/fire-hydrant-connections-mechanical-joint-valve-fittings.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Install-12<\/a><\/td><td><strong>Fire Hydrant Connections Mechanical Joint Valve &amp; Fittings<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/fire-hydrant-connections-mechanical-joint-valve-fittings.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pressure-test-setup.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Install-13<\/a><\/td><td><strong>Pressure Test Setup<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pressure-test-setup.dwg\">DWG<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"has-text-align-center wp-block-heading\" id=\"thrust\">Thrust<\/h4>\n\n\n\n<figure class=\"wp-block-table alignwide mt0\"><table><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Detail ID<\/th><th><strong>Detail Name<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\">CAD File<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-tees.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Thrust-01<\/a><\/td><td><strong>Concrete Anchors for Tees<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-tees.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-1-4-bends.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Thrust-02<\/a><\/td><td><strong>Concrete Anchors for Horizontal 1\/4 Bends<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-1-4-bends.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-1-8-bends.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Thrust-03<\/a><\/td><td><strong>Concrete Anchors for Horizontal 1\/8 Bends<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-1-8-bends.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-1-16-bends.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Thrust-04<\/a><\/td><td><strong>Concrete Anchors for Horizontal 1\/16 and 1\/32 Bends<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-1-16-bends.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-vertical-bends-top.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Thrust-05-A<\/a><\/td><td><strong>Concrete Anchors for Vertical Bends (Top) Pg 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-vertical-bends.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-vertical-bends-top-2.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Thrust-05-B<\/a><\/td><td><strong>Concrete Anchors for Vertical Bends (Top) Pg 2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2013<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-vert-bends-bottom.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Thrust-06<\/a><\/td><td><strong>Concrete Anchors for Vertical Bends (Bot)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-vertical-bends-bottom.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-dead-ends.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Thrust-07<\/a><\/td><td><strong>Concrete Anchors for Dead Ends<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-anchors-for-dead-ends.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/push-on-joint-harnessing.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Thrust-08<\/a><\/td><td><strong>Push On Joint Harnessing<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/push-on-joint-harnessing.dwg\">DWG<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"has-text-align-center wp-block-heading\" id=\"valve\">Valve<\/h4>\n\n\n\n<figure class=\"wp-block-table alignwide mt0\"><table><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Detail ID<\/th><th><strong>Detail Name<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\">CAD File<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/direct-bury-valve.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Valve-01<\/a><\/td><td><strong>Direct Bury Valve<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/valve-direct-bury.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/air-valves.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Valve-03<\/a><\/td><td><strong>Air Valves<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/air-valves.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/air-valve-chamber.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Valve-04<\/a><\/td><td><strong>Air Valve Chamber<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/automatic-air-valve-chamber.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/blow-off-branch-with-outlet-valve.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Valve-05<\/a><\/td><td><strong>Blow-Off Branch with Outlet Valve<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/blow-off-branch-with-outlet-valve.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/blow-off-chamber.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Valve-06<\/a><\/td><td><strong>Blow-Off Chamber<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/blow-off-chamber.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/21-34-diameter-manhole-frame-and-cover-blow-off-branch-with-outlet-valve.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Valve-07<\/a><\/td><td><strong>Frame and Cover 21&#8243; 3\/4&#8243;<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/21-3-4-diameter-manhole-frame-and-cover.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/36-diameter-manhole-frame-and-cover-blow-off-branch-with-outlet-valve.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Valve-08<\/a><\/td><td><strong>Frame and Cover 36&#8243;<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/36-diameter-manhole-frame-and-cover.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/manhole-steps.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Valve-09<\/a><\/td><td><strong>Manhole Steps<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/manhole-steps.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/valve-concrete-pad.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Valve-10<\/a><\/td><td><strong>Valve Concrete Pad<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/valve-concrete-pad.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/7-valve-box-cast-iron-frame-and-cover.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Valve-12<\/a><\/td><td><strong>Standard 7&#8243; Valve Box Cast Iron Frame and Cover<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/7-cast-iron-valve-box.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-7-valve-box-plastic-top-bottom-section.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Valve-13-A<\/a><\/td><td><strong>Standard 7&#8243; Valve Box Plastic Top &amp; Bottom Section<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-7-plastic-valve-box-cast-iron-cover-frame-top-section.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-7-valve-box-plastic-materials-specifications-pg-2.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Valve-13-B<\/a><\/td><td><strong>Standard 7&#8243; Valve Box Materials Specifications<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2013<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Jump to: Install Thrust Valve Files: Table of Contents Install Detail ID Detail Name CAD File Install-01 Push on Joint Assembly Detail DWG Install-02 Mechanical Joint Assembly Detail Wedge DWG Install-03 Pay Limits for Excavation of Water Main Trenches DWG Install-04 Excavation Pay Limit Dimensions DWG Install-05 Trench Restoration Detail \u2013 City Streets DWG Install-06 [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":70,"comment_status":"closed","ping_status":"closed","template":"page-w-sidebar.php","meta":{"custom_css":"tr td:first-child { white-space: nowrap; }","dp_submitted":"0","dp_notify":"0","dp_created":"2022-09-15 17:49:30","custom_js":"","pwd_rlv_phrase_match":"water standard details | water standard details | jump to | install thrust valve | files | compiled water standard details list | water standard cad files | table of contents | install | detail id detail name cad file install 01 push on joint assembly detail dwg install 02 mechanical joint assembly detail wedge dwg install 03 pay limits for excavation of water main trenches dwg install 04 excavation pay limit dimensions dwg install 05 trench restoration detail city streets dwg install 06 paving dimensions quantities city streets dwg install 07 trench restoration detail state routes install 08 paving dimensions quantities state routes install 09 frost protective coating dwg install 10 a service connections 2 and smaller pg 1 install 10 b service connections 2 and smaller pg 2 install 11 fire hydrant installation dwg install 12 fire hydrant connections mechanical joint valve fittings dwg install 13 pressure test setup dwg | thrust | detail id detail name cad file thrust 01 concrete anchors for tees dwg thrust 02 concrete anchors for horizontal 1 4 bends dwg thrust 03 concrete anchors for horizontal 1 8 bends dwg thrust 04 concrete anchors for horizontal 1 16 and 1 32 bends dwg thrust 05 a concrete anchors for vertical bends top pg 1 dwg thrust 05 b concrete anchors for vertical bends top pg 2 thrust 06 concrete anchors for vertical bends bot dwg thrust 07 concrete anchors for dead ends dwg thrust 08 push on joint harnessing dwg | valve | detail id detail name cad file valve 01 direct bury valve dwg valve 03 air valves dwg valve 04 air valve chamber dwg valve 05 blow off branch with outlet valve dwg valve 06 blow off chamber dwg valve 07 frame and cover 21 3 4 dwg valve 08 frame and cover 36 dwg valve 09 manhole steps dwg valve 10 valve concrete pad dwg valve 12 standard 7 valve box cast iron frame and cover dwg valve 13 a standard 7 valve box plastic top bottom section dwg valve 13 b standard 7 valve box materials specifications","pwd_rlv_wordcount":"274"},"section":[],"class_list":["post-16","page","type-page","status-publish","hentry","wpautop"],"acf":[],"parsely":{"version":"1.1.0","canonical_url":"https:\/\/phila.gov\/design\/water-standard-details\/","smart_links":{"inbound":0,"outbound":0},"traffic_boost_suggestions_count":0,"meta":{"@context":"https:\/\/schema.org","@type":"WebPage","headline":"Water Standard Details","url":"http:\/\/water.phila.gov\/design\/water-standard-details\/","mainEntityOfPage":{"@type":"WebPage","@id":"http:\/\/water.phila.gov\/design\/water-standard-details\/"},"thumbnailUrl":"","image":{"@type":"ImageObject","url":""},"articleSection":"Uncategorized","author":[{"@type":"Person","name":"Lauren Sell"}],"creator":["Lauren Sell"],"publisher":{"@type":"Organization","name":"Water &amp; Sewer Design","logo":""},"keywords":[],"dateCreated":"2021-05-07T19:11:44Z","datePublished":"2021-05-07T19:11:44Z","dateModified":"2022-11-09T17:54:51Z"},"rendered":"<script type=\"application\/ld+json\" class=\"wp-parsely-metadata\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@type\":\"WebPage\",\"headline\":\"Water Standard Details\",\"url\":\"http:\\\/\\\/water.phila.gov\\\/design\\\/water-standard-details\\\/\",\"mainEntityOfPage\":{\"@type\":\"WebPage\",\"@id\":\"http:\\\/\\\/water.phila.gov\\\/design\\\/water-standard-details\\\/\"},\"thumbnailUrl\":\"\",\"image\":{\"@type\":\"ImageObject\",\"url\":\"\"},\"articleSection\":\"Uncategorized\",\"author\":[{\"@type\":\"Person\",\"name\":\"Lauren Sell\"}],\"creator\":[\"Lauren Sell\"],\"publisher\":{\"@type\":\"Organization\",\"name\":\"Water &amp; Sewer Design\",\"logo\":\"\"},\"keywords\":[],\"dateCreated\":\"2021-05-07T19:11:44Z\",\"datePublished\":\"2021-05-07T19:11:44Z\",\"dateModified\":\"2022-11-09T17:54:51Z\"}<\/script>","tracker_url":"https:\/\/cdn.parsely.com\/keys\/phila.gov\/p.js"},"_links":{"self":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages\/16","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/comments?post=16"}],"version-history":[{"count":0,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages\/16\/revisions"}],"wp:attachment":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/media?parent=16"}],"wp:term":[{"taxonomy":"section","embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/section?post=16"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}