{"id":19,"date":"2021-05-06T20:12:52","date_gmt":"2021-05-07T00:12:52","guid":{"rendered":"https:\/\/water.phila.gov\/design\/?page_id=19"},"modified":"2022-10-18T20:05:34","modified_gmt":"2022-10-19T00:05:34","slug":"sewer-standard-details","status":"publish","type":"page","link":"https:\/\/water.phila.gov\/design\/sewer-standard-details\/","title":{"rendered":"Sewer Standard Details and Specifications"},"content":{"rendered":"\n<div class=\"wp-block-columns fa-stretch is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Jump to:<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li><a href=\"#details\">Details<\/a><ul><li><a href=\"#pipe\">Pipe<\/a><\/li><li><a href=\"#connection\">Connection<\/a><\/li><li><a href=\"#manhole\">Manhole<\/a><\/li><li><a href=\"#inlet\">Inlet<\/a><\/li><\/ul><\/li><li><a href=\"#specifications\">Specifications<\/a><\/li><\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Files:<\/h3>\n\n\n\n<div class=\"wp-block-buttons fa-stretch is-vertical is-layout-flex wp-container-core-buttons-is-layout-8cf370e7 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Standard Version<\/a><\/div>\n\n\n\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Engineering Version<\/a><\/div>\n\n\n\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-standards.ctb\">PWD Standards CTB File<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"has-text-align-center mt_5 wp-block-heading\" id=\"table-of-contents\">Table of Contents<\/h2>\n\n\n\n<h3 class=\"has-text-align-center mt_5 wp-block-heading\" id=\"details\">Details<\/h3>\n\n\n\n<h4 class=\"has-text-align-center mt0 wp-block-heading\" id=\"pipe\">PIPE<\/h4>\n\n\n\n<figure class=\"wp-block-table alignwide\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf\" target=\"_blank\">Standard Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">Detail<\/th><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Engineering Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">CAD File<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=6\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-01<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Vitrified Clay Pipe Sewer<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=4\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/vc-pipe-sewer.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=7\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-02<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>R.C. Pipe Sewer or Stormwater Conduit<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=5\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/rc-pipe-sewer-or-stormwater-conduit.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=8\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-03<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Vit. Clay Pipe Sewer with R.C. Pipe SW. Conduit<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=6\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/seperate-system.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=9\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-04<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Typical Street Section<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=7\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/typical-street-section.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=10\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-05<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Typical Lateral Risers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=8\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/typical-lateral-risers.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=11\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-06<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Stormwater Turnout for Separate System<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=9\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/seperate-system-turnouts.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=12\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-07<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Collar<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=10\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-collars.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=13\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-08<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Embankment Over Pipes<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=11\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/embankment-over-pipes.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=14\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-09<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Pipe Endwall<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=12\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pipe-endwall.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=15\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-10<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Pipe Headwall<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=13\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pipe-headwall.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=16\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-11<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Chain Link Fence<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=14\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/chain-link-fence.dwg\">DWG<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"has-text-align-center wp-block-heading\" id=\"connection\">CONNECTION<\/h4>\n\n\n\n<figure class=\"wp-block-table alignwide\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf\" target=\"_blank\">Standard Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">Detail<\/th><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Engineering Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">CAD File<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=17\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-01<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Cut-off Wall<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=15\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-cutoff-wall.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=18\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-02<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Intentionally Left Blank<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"> <\/td><td class=\"has-text-align-center\" data-align=\"center\"> <\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=19\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-03<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Saddle Connection<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=17\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/saddle-connection.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=20\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-04<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Modified Saddle Connection to Circular Sewers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=18\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/modified-saddle-connection-to-circ-br-sw.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=21\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-05<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Modified Saddle Connection to Egg Shaped Sewers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=19\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/modified-saddle-connection-to-egg-shaped-sewer.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=22\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-06<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Doghouse Manhole Connection to Circular Sewers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=20\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/doghouse-manhole-connection-std-details.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=23\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-07<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Doghouse Manhole Connection to Egg Shaped Sewers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=21\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/doghouse-manhole-connection-std-details.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=24\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-08<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Combined System Vent Connection<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=22\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/vent-connection.dwg\">DWG<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"has-text-align-center wp-block-heading\" id=\"manhole\">MANHOLE<\/h4>\n\n\n\n<figure class=\"wp-block-table alignwide\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf\" target=\"_blank\">Standard Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">Detail<\/th><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Engineering Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">CAD File<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=25\" target=\"_blank\" rel=\"noreferrer noopener\">MH-01<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Manhole Riser &amp; Cone<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=23\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-manhole-riser-and-cone.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=26\" target=\"_blank\" rel=\"noreferrer noopener\">MH-02<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Manhole Base &#8211; Pipe \u2264 30&#8243; &#8211; Combined<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=24\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-manhole-base-30-and-under.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=27\" target=\"_blank\" rel=\"noreferrer noopener\">MH-03<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Doghouse Manhole &#8211; Pipe \u2264 30&#8243;<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=25\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/doghouse-manhole-on-30-under-sewer.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=28\" target=\"_blank\" rel=\"noreferrer noopener\">MH-04<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Manhole Bases &#8211; Pipe \u2264 30&#8243;<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=26\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-manhole-base.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=29\" target=\"_blank\" rel=\"noreferrer noopener\">MH-05<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Manhole Base &#8211; Pipe \u2265 36&#8243; &#8211; Combined<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=27\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-manhole-base-36-and-over.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=30\" target=\"_blank\" rel=\"noreferrer noopener\">MH-06<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Manhole Base &#8211; Pipe \u2264 30&#8243; &#8211; Seperate<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=28\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-manhole-base-separate-system-sw-30-dia-and-under.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=31\" target=\"_blank\" rel=\"noreferrer noopener\">MH-07<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Manhole Base &#8211; Pipe \u2265 36&#8243; &#8211; Separate<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=29\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-manhole-base-seperate-system-sw-36-dia-and-over.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=32\" target=\"_blank\" rel=\"noreferrer noopener\">MH-08<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Manhole Base &#8211; Junction Manhole<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=30\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/junction-manhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=33\" target=\"_blank\" rel=\"noreferrer noopener\">MH-09<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Summit Manhole<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=31\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/summit-manhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=34\" target=\"_blank\" rel=\"noreferrer noopener\">MH-10<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Drop Manhole<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=32\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-drop-manhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=35\" target=\"_blank\" rel=\"noreferrer noopener\">MH-11-A<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Interior Drop Manhole Pg 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=33\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-interior-drop-manhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=36\" target=\"_blank\" rel=\"noreferrer noopener\">MH-11-B<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Interior Drop Manhole Pg 2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=34\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-interior-drop-manhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=37\" target=\"_blank\" rel=\"noreferrer noopener\">MH-11-C<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Interior Drop Manhole Pg 3<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=35\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-interior-drop-manhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=38\" target=\"_blank\" rel=\"noreferrer noopener\">MH-12-A<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Wellhole Pg 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=36\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/wellhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=39\" target=\"_blank\" rel=\"noreferrer noopener\">MH-12-B<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Wellhole Pg 2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=37\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/wellhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=40\" target=\"_blank\" rel=\"noreferrer noopener\">MH-13-A<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Gray Iron Manhole Frame &amp; Covers Pg 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=38\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/manhole-cover.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=41\" target=\"_blank\" rel=\"noreferrer noopener\">MH-13-B<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Gray Iron Manhole Frame &amp; Covers Pg 2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=39\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/manhole-cover.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=42\" target=\"_blank\" rel=\"noreferrer noopener\">MH-14<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Manhole Steps<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=40\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/manhole-steps-sewer.dwg\">DWG<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"has-text-align-center wp-block-heading\" id=\"inlet\">INLET<\/h4>\n\n\n\n<figure class=\"wp-block-table alignwide\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf\" target=\"_blank\">Standard Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">Detail<\/th><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Engineering Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">CAD File<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=43\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-01<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Assembly of Precast Inlets<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=41\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/catch-basin-assemblies.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=44\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-02<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Open Mouth Grate Inlet Assembly<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=42\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/catch-basin-assemblies.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=45\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-03<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Highway Grate Inlet Assembly<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=43\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/catch-basin-assemblies.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=46\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-04<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Gutter Grate Inlet Assembly<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=44\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/catch-basin-assemblies.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page-47\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-05<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Open Mouth Inlet Assembly<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=45\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/catch-basin-assemblies.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=48\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-06-A<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Inlet and Trap Installation Pg 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=46\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/inlet-and-trap-installation.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=49\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-06-B<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Inlet and Trap Installation Pg 2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=47\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/inlet-and-trap-installation.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=50\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-07<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Two-Piece Precast Catch Basin<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=48\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/two-piece-catch-basin.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=51\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-08<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Inlet Trap<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=49\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/inlet-trap.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=52\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-09<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Reinforced Inlet Hood<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=50\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-inlet-hood.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=53\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-10<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Highway Grate and Gutter Grate Inlet Adjustment Risers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=51\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/highway-grate-and-gutter-grate-inlet-adjustment-risers.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=54\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-11<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Inlet Frames<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=52\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/inlet-frames.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=55\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-12<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Inlet Grates<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=53\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/inlet-grates.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=56\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-13<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Apron at Open Mouth Grate Inlet<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=54\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-apron.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=57\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-14<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Open Mouth Inlet Adjustment Risers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=55\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/open-mouth-inlet-adjustment-risers.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=58\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-15<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Top Slabs<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=56\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-top-slabs.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-16<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Top Slab Clean-out Cover &amp; Frame<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=57\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/top-slab-clean-out-cover-frame.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-17<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Apron at Open Mouth Inlet<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=58\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-apron.dwg\">DWG<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"has-text-align-center wp-block-heading\" id=\"specifications\">SPECIFICATIONS<\/h3>\n\n\n\n<figure class=\"wp-block-table alignwide\"><table><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf\" target=\"_blank\">Standard Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">Specification<\/th><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf\" target=\"_blank\">Engineering Version<\/a><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=61\" target=\"_blank\" rel=\"noreferrer noopener\">D-1<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-1: GENERAL<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=61\" target=\"_blank\" rel=\"noreferrer noopener\">D-2<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-2: STANDARD DETAILS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=61\" target=\"_blank\" rel=\"noreferrer noopener\">D-3<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-3: ABBREVIATIONS AND DEFINITIONS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=62\" target=\"_blank\" rel=\"noreferrer noopener\">D-4<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-4: REQUIREMENTS, TESTS AND INSPECTIONS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=62\" target=\"_blank\" rel=\"noreferrer noopener\">D-5<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-5: LINES AND GRADES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=62\" target=\"_blank\" rel=\"noreferrer noopener\">D-6<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-6: WIDTH OF TRENCHES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=62\" target=\"_blank\" rel=\"noreferrer noopener\">D-7<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-7: INSTALLATION OF PIPES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=63\" target=\"_blank\" rel=\"noreferrer noopener\">D-8<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-8: PROTECTION OF PIPES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=63\" target=\"_blank\" rel=\"noreferrer noopener\">D-9<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-9: LENGTH OF PIPES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=63\" target=\"_blank\" rel=\"noreferrer noopener\">D-10<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-10: PROVISIONS FOR LATERAL CONNECTIONS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=63\">D-11<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-11: MEASUREMENT FOR PAYMENT<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">D-12<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-12: FILLING ABANDONED SEWERS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">D-13<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-13: FILLING ABANDONED MANHOLES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">D-14<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-14: FILLING ABANDONED INLETS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">D-15<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-15: VITRIFIED CLAY PIPE<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=65\" target=\"_blank\" rel=\"noreferrer noopener\">D-16<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-16: REINFORCED CONCRETE PIPE<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=61\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=66\" target=\"_blank\" rel=\"noreferrer noopener\">D-17<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-17: CAST-IN-PLACE, REINFORCED CONCRETE CONCRETE SEWERS, STORMWATER CONDUITS AND SPECIAL SECTIONS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=61\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=68\" target=\"_blank\" rel=\"noreferrer noopener\">D-18<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-18: PRECAST, REINFORCED CONCRETE SEWERS AND STORMWATER CONDUITS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=62\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=70\" target=\"_blank\" rel=\"noreferrer noopener\">D-19<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-19: DUCTILE IRON PIPE<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=63\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=71\" target=\"_blank\" rel=\"noreferrer noopener\">D-20<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-20: CAST IRON SOIL PIPE<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=71\" target=\"_blank\" rel=\"noreferrer noopener\">D-21<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-21: MANHOLES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=72\" target=\"_blank\" rel=\"noreferrer noopener\">D-22<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-22: WELLHOLES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=74\" target=\"_blank\" rel=\"noreferrer noopener\">D-23<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-23: INLETS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=65\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=78\" target=\"_blank\" rel=\"noreferrer noopener\">D-24<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-24: CHAIN LINK FENCE<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=67\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=81\" target=\"_blank\" rel=\"noreferrer noopener\">STRD<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Standard, Codes, and other references in the Standard Specs<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=69\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Jump to: Details Pipe Connection Manhole Inlet Specifications Files: Table of Contents Details PIPE Standard Version Detail Engineering Version CAD File PIPE-01 Vitrified Clay Pipe Sewer ENGR DWG PIPE-02 R.C. Pipe Sewer or Stormwater Conduit ENGR DWG PIPE-03 Vit. Clay Pipe Sewer with R.C. Pipe SW. Conduit ENGR DWG PIPE-04 Typical Street Section ENGR DWG [&hellip;]<\/p>\n","protected":false},"author":26,"featured_media":0,"parent":0,"menu_order":60,"comment_status":"closed","ping_status":"closed","template":"page-w-sidebar.php","meta":{"custom_css":".wp-block-column ul li { padding-top: .25em; }\r\nfigure.wp-block-table { margin-top: 0; }\r\nth a { color: #fff !important; }\r\ntbody a:after { display: none; }","dp_submitted":"0","dp_notify":"0","dp_created":"","custom_js":""},"section":[],"class_list":["post-19","page","type-page","status-publish","hentry","wpautop"],"acf":[],"parsely":{"version":"1.1.0","canonical_url":"https:\/\/phila.gov\/design\/sewer-standard-details\/","smart_links":{"inbound":0,"outbound":0},"traffic_boost_suggestions_count":0,"meta":{"@context":"https:\/\/schema.org","@type":"WebPage","headline":"Sewer Standard Details and Specifications","url":"http:\/\/water.phila.gov\/design\/sewer-standard-details\/","mainEntityOfPage":{"@type":"WebPage","@id":"http:\/\/water.phila.gov\/design\/sewer-standard-details\/"},"thumbnailUrl":"","image":{"@type":"ImageObject","url":""},"articleSection":"Uncategorized","author":[{"@type":"Person","name":"Justin Martin"}],"creator":["Justin Martin"],"publisher":{"@type":"Organization","name":"Water &amp; Sewer Design","logo":""},"keywords":[],"dateCreated":"2021-05-07T00:12:52Z","datePublished":"2021-05-07T00:12:52Z","dateModified":"2022-10-19T00:05:34Z"},"rendered":"<script type=\"application\/ld+json\" class=\"wp-parsely-metadata\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@type\":\"WebPage\",\"headline\":\"Sewer Standard Details and Specifications\",\"url\":\"http:\\\/\\\/water.phila.gov\\\/design\\\/sewer-standard-details\\\/\",\"mainEntityOfPage\":{\"@type\":\"WebPage\",\"@id\":\"http:\\\/\\\/water.phila.gov\\\/design\\\/sewer-standard-details\\\/\"},\"thumbnailUrl\":\"\",\"image\":{\"@type\":\"ImageObject\",\"url\":\"\"},\"articleSection\":\"Uncategorized\",\"author\":[{\"@type\":\"Person\",\"name\":\"Justin Martin\"}],\"creator\":[\"Justin Martin\"],\"publisher\":{\"@type\":\"Organization\",\"name\":\"Water &amp; Sewer Design\",\"logo\":\"\"},\"keywords\":[],\"dateCreated\":\"2021-05-07T00:12:52Z\",\"datePublished\":\"2021-05-07T00:12:52Z\",\"dateModified\":\"2022-10-19T00:05:34Z\"}<\/script>","tracker_url":"https:\/\/cdn.parsely.com\/keys\/phila.gov\/p.js"},"_links":{"self":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages\/19","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/users\/26"}],"replies":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/comments?post=19"}],"version-history":[{"count":0,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages\/19\/revisions"}],"wp:attachment":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/media?parent=19"}],"wp:term":[{"taxonomy":"section","embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/section?post=19"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}