{"id":19,"date":"2021-05-06T20:12:52","date_gmt":"2021-05-07T00:12:52","guid":{"rendered":"https:\/\/water.phila.gov\/design\/?page_id=19"},"modified":"2022-10-18T20:05:34","modified_gmt":"2022-10-19T00:05:34","slug":"sewer-standard-details","status":"publish","type":"page","link":"https:\/\/water.phila.gov\/design\/sewer-standard-details\/","title":{"rendered":"Sewer Standard Details and Specifications"},"content":{"rendered":"\n<div class=\"wp-block-columns fa-stretch is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Jump to:<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li><a href=\"#details\">Details<\/a><ul><li><a href=\"#pipe\">Pipe<\/a><\/li><li><a href=\"#connection\">Connection<\/a><\/li><li><a href=\"#manhole\">Manhole<\/a><\/li><li><a href=\"#inlet\">Inlet<\/a><\/li><\/ul><\/li><li><a href=\"#specifications\">Specifications<\/a><\/li><\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Files:<\/h3>\n\n\n\n<div class=\"wp-block-buttons fa-stretch is-vertical is-layout-flex wp-container-core-buttons-is-layout-8cf370e7 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Standard Version<\/a><\/div>\n\n\n\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Engineering Version<\/a><\/div>\n\n\n\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pwd-standards.ctb\">PWD Standards CTB File<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"has-text-align-center mt_5 wp-block-heading\" id=\"table-of-contents\">Table of Contents<\/h2>\n\n\n\n<h3 class=\"has-text-align-center mt_5 wp-block-heading\" id=\"details\">Details<\/h3>\n\n\n\n<h4 class=\"has-text-align-center mt0 wp-block-heading\" id=\"pipe\">PIPE<\/h4>\n\n\n\n<figure class=\"wp-block-table alignwide\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf\" target=\"_blank\">Standard Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">Detail<\/th><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Engineering Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">CAD File<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=6\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-01<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Vitrified Clay Pipe Sewer<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=4\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/vc-pipe-sewer.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=7\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-02<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>R.C. Pipe Sewer or Stormwater Conduit<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=5\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/rc-pipe-sewer-or-stormwater-conduit.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=8\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-03<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Vit. Clay Pipe Sewer with R.C. Pipe SW. Conduit<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=6\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/seperate-system.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=9\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-04<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Typical Street Section<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=7\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/typical-street-section.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=10\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-05<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Typical Lateral Risers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=8\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/typical-lateral-risers.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=11\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-06<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Stormwater Turnout for Separate System<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=9\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/seperate-system-turnouts.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=12\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-07<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Collar<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=10\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-collars.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=13\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-08<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Embankment Over Pipes<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=11\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/embankment-over-pipes.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=14\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-09<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Pipe Endwall<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=12\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pipe-endwall.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=15\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-10<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Pipe Headwall<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=13\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/pipe-headwall.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=16\" target=\"_blank\" rel=\"noreferrer noopener\">PIPE-11<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Chain Link Fence<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=14\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/chain-link-fence.dwg\">DWG<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"has-text-align-center wp-block-heading\" id=\"connection\">CONNECTION<\/h4>\n\n\n\n<figure class=\"wp-block-table alignwide\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf\" target=\"_blank\">Standard Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">Detail<\/th><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Engineering Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">CAD File<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=17\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-01<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Cut-off Wall<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=15\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-cutoff-wall.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=18\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-02<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Intentionally Left Blank<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"> <\/td><td class=\"has-text-align-center\" data-align=\"center\"> <\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=19\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-03<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Saddle Connection<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=17\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/saddle-connection.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=20\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-04<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Modified Saddle Connection to Circular Sewers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=18\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/modified-saddle-connection-to-circ-br-sw.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=21\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-05<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Modified Saddle Connection to Egg Shaped Sewers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=19\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/modified-saddle-connection-to-egg-shaped-sewer.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=22\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-06<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Doghouse Manhole Connection to Circular Sewers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=20\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/doghouse-manhole-connection-std-details.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=23\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-07<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Doghouse Manhole Connection to Egg Shaped Sewers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=21\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/doghouse-manhole-connection-std-details.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=24\" target=\"_blank\" rel=\"noreferrer noopener\">CONN-08<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Combined System Vent Connection<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=22\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/vent-connection.dwg\">DWG<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"has-text-align-center wp-block-heading\" id=\"manhole\">MANHOLE<\/h4>\n\n\n\n<figure class=\"wp-block-table alignwide\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf\" target=\"_blank\">Standard Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">Detail<\/th><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Engineering Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">CAD File<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=25\" target=\"_blank\" rel=\"noreferrer noopener\">MH-01<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Manhole Riser &amp; Cone<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=23\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-manhole-riser-and-cone.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=26\" target=\"_blank\" rel=\"noreferrer noopener\">MH-02<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Manhole Base &#8211; Pipe \u2264 30&#8243; &#8211; Combined<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=24\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-manhole-base-30-and-under.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=27\" target=\"_blank\" rel=\"noreferrer noopener\">MH-03<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Doghouse Manhole &#8211; Pipe \u2264 30&#8243;<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=25\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/doghouse-manhole-on-30-under-sewer.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=28\" target=\"_blank\" rel=\"noreferrer noopener\">MH-04<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Manhole Bases &#8211; Pipe \u2264 30&#8243;<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=26\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-manhole-base.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=29\" target=\"_blank\" rel=\"noreferrer noopener\">MH-05<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Manhole Base &#8211; Pipe \u2265 36&#8243; &#8211; Combined<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=27\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-manhole-base-36-and-over.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=30\" target=\"_blank\" rel=\"noreferrer noopener\">MH-06<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Manhole Base &#8211; Pipe \u2264 30&#8243; &#8211; Seperate<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=28\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-manhole-base-separate-system-sw-30-dia-and-under.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=31\" target=\"_blank\" rel=\"noreferrer noopener\">MH-07<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Manhole Base &#8211; Pipe \u2265 36&#8243; &#8211; Separate<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=29\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-manhole-base-seperate-system-sw-36-dia-and-over.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=32\" target=\"_blank\" rel=\"noreferrer noopener\">MH-08<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Manhole Base &#8211; Junction Manhole<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=30\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/junction-manhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=33\" target=\"_blank\" rel=\"noreferrer noopener\">MH-09<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Summit Manhole<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=31\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/summit-manhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=34\" target=\"_blank\" rel=\"noreferrer noopener\">MH-10<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Drop Manhole<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=32\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-drop-manhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=35\" target=\"_blank\" rel=\"noreferrer noopener\">MH-11-A<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Interior Drop Manhole Pg 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=33\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-interior-drop-manhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=36\" target=\"_blank\" rel=\"noreferrer noopener\">MH-11-B<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Interior Drop Manhole Pg 2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=34\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-interior-drop-manhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=37\" target=\"_blank\" rel=\"noreferrer noopener\">MH-11-C<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Interior Drop Manhole Pg 3<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=35\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-interior-drop-manhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=38\" target=\"_blank\" rel=\"noreferrer noopener\">MH-12-A<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Wellhole Pg 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=36\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/wellhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=39\" target=\"_blank\" rel=\"noreferrer noopener\">MH-12-B<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Wellhole Pg 2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=37\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/wellhole.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=40\" target=\"_blank\" rel=\"noreferrer noopener\">MH-13-A<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Gray Iron Manhole Frame &amp; Covers Pg 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=38\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/manhole-cover.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=41\" target=\"_blank\" rel=\"noreferrer noopener\">MH-13-B<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Gray Iron Manhole Frame &amp; Covers Pg 2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=39\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/manhole-cover.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=42\" target=\"_blank\" rel=\"noreferrer noopener\">MH-14<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Manhole Steps<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=40\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/manhole-steps-sewer.dwg\">DWG<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"has-text-align-center wp-block-heading\" id=\"inlet\">INLET<\/h4>\n\n\n\n<figure class=\"wp-block-table alignwide\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf\" target=\"_blank\">Standard Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">Detail<\/th><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Engineering Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">CAD File<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=43\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-01<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Assembly of Precast Inlets<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=41\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/catch-basin-assemblies.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=44\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-02<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Open Mouth Grate Inlet Assembly<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=42\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/catch-basin-assemblies.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=45\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-03<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Highway Grate Inlet Assembly<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=43\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/catch-basin-assemblies.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=46\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-04<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Gutter Grate Inlet Assembly<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=44\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/catch-basin-assemblies.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page-47\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-05<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Open Mouth Inlet Assembly<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=45\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/catch-basin-assemblies.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=48\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-06-A<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Inlet and Trap Installation Pg 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=46\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/inlet-and-trap-installation.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=49\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-06-B<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Inlet and Trap Installation Pg 2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=47\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/inlet-and-trap-installation.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=50\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-07<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Two-Piece Precast Catch Basin<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=48\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/two-piece-catch-basin.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=51\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-08<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Inlet Trap<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=49\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/inlet-trap.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=52\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-09<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Reinforced Inlet Hood<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=50\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-inlet-hood.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=53\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-10<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Highway Grate and Gutter Grate Inlet Adjustment Risers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=51\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/highway-grate-and-gutter-grate-inlet-adjustment-risers.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=54\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-11<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Inlet Frames<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=52\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/inlet-frames.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=55\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-12<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Inlet Grates<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=53\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/inlet-grates.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=56\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-13<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Apron at Open Mouth Grate Inlet<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=54\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-apron.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=57\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-14<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Open Mouth Inlet Adjustment Risers<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=55\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/open-mouth-inlet-adjustment-risers.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=58\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-15<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precast Concrete Top Slabs<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=56\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/precast-concrete-top-slabs.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-16<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Top Slab Clean-out Cover &amp; Frame<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=57\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/top-slab-clean-out-cover-frame.dwg\">DWG<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">INLET-17<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Concrete Apron at Open Mouth Inlet<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=58\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/concrete-apron.dwg\">DWG<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"has-text-align-center wp-block-heading\" id=\"specifications\">SPECIFICATIONS<\/h3>\n\n\n\n<figure class=\"wp-block-table alignwide\"><table><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf\" target=\"_blank\">Standard Version<\/a><\/th><th class=\"has-text-align-center\" data-align=\"center\">Specification<\/th><th class=\"has-text-align-center\" data-align=\"center\"><a class=\"has-white-color\" rel=\"noreferrer noopener\" href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf\" target=\"_blank\">Engineering Version<\/a><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=61\" target=\"_blank\" rel=\"noreferrer noopener\">D-1<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-1: GENERAL<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=61\" target=\"_blank\" rel=\"noreferrer noopener\">D-2<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-2: STANDARD DETAILS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=61\" target=\"_blank\" rel=\"noreferrer noopener\">D-3<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-3: ABBREVIATIONS AND DEFINITIONS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=62\" target=\"_blank\" rel=\"noreferrer noopener\">D-4<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-4: REQUIREMENTS, TESTS AND INSPECTIONS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=62\" target=\"_blank\" rel=\"noreferrer noopener\">D-5<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-5: LINES AND GRADES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=62\" target=\"_blank\" rel=\"noreferrer noopener\">D-6<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-6: WIDTH OF TRENCHES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=62\" target=\"_blank\" rel=\"noreferrer noopener\">D-7<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-7: INSTALLATION OF PIPES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=59\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=63\" target=\"_blank\" rel=\"noreferrer noopener\">D-8<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-8: PROTECTION OF PIPES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=63\" target=\"_blank\" rel=\"noreferrer noopener\">D-9<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-9: LENGTH OF PIPES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=63\" target=\"_blank\" rel=\"noreferrer noopener\">D-10<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-10: PROVISIONS FOR LATERAL CONNECTIONS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=63\">D-11<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-11: MEASUREMENT FOR PAYMENT<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">D-12<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-12: FILLING ABANDONED SEWERS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">D-13<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-13: FILLING ABANDONED MANHOLES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">D-14<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-14: FILLING ABANDONED INLETS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">D-15<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-15: VITRIFIED CLAY PIPE<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=60\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=65\" target=\"_blank\" rel=\"noreferrer noopener\">D-16<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-16: REINFORCED CONCRETE PIPE<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=61\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=66\" target=\"_blank\" rel=\"noreferrer noopener\">D-17<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-17: CAST-IN-PLACE, REINFORCED CONCRETE CONCRETE SEWERS, STORMWATER CONDUITS AND SPECIAL SECTIONS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=61\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=68\" target=\"_blank\" rel=\"noreferrer noopener\">D-18<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-18: PRECAST, REINFORCED CONCRETE SEWERS AND STORMWATER CONDUITS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=62\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=70\" target=\"_blank\" rel=\"noreferrer noopener\">D-19<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-19: DUCTILE IRON PIPE<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=63\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=71\" target=\"_blank\" rel=\"noreferrer noopener\">D-20<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-20: CAST IRON SOIL PIPE<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=71\" target=\"_blank\" rel=\"noreferrer noopener\">D-21<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-21: MANHOLES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=72\" target=\"_blank\" rel=\"noreferrer noopener\">D-22<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-22: WELLHOLES<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=64\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=74\" target=\"_blank\" rel=\"noreferrer noopener\">D-23<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-23: INLETS<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=65\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=78\" target=\"_blank\" rel=\"noreferrer noopener\">D-24<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>D-24: CHAIN LINK FENCE<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=67\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-and-specifications-for-sewers.pdf#page=81\" target=\"_blank\" rel=\"noreferrer noopener\">STRD<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Standard, Codes, and other references in the Standard Specs<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/files\/standard-details-engineering.pdf#page=69\" target=\"_blank\" rel=\"noreferrer noopener\">ENGR<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Jump to: Details Pipe Connection Manhole Inlet Specifications Files: Table of Contents Details PIPE Standard Version Detail Engineering Version CAD File PIPE-01 Vitrified Clay Pipe Sewer ENGR DWG PIPE-02 R.C. Pipe Sewer or Stormwater Conduit ENGR DWG PIPE-03 Vit. Clay Pipe Sewer with R.C. Pipe SW. Conduit ENGR DWG PIPE-04 Typical Street Section ENGR DWG [&hellip;]<\/p>\n","protected":false},"author":26,"featured_media":0,"parent":0,"menu_order":60,"comment_status":"closed","ping_status":"closed","template":"page-w-sidebar.php","meta":{"custom_css":".wp-block-column ul li { padding-top: .25em; }\r\nfigure.wp-block-table { margin-top: 0; }\r\nth a { color: #fff !important; }\r\ntbody a:after { display: none; }","dp_submitted":"0","dp_notify":"0","dp_created":"","custom_js":"","pwd_rlv_phrase_match":"sewer standard details and specifications | sewer standard details | jump to | details pipe connection manhole inlet specifications | files | standard version | engineering version | pwd standards ctb file | table of contents | details | pipe | standard version detail engineering version cad file pipe 01 vitrified clay pipe sewer engr dwg pipe 02 r c pipe sewer or stormwater conduit engr dwg pipe 03 vit clay pipe sewer with r c pipe sw conduit engr dwg pipe 04 typical street section engr dwg pipe 05 typical lateral risers engr dwg pipe 06 stormwater turnout for separate system engr dwg pipe 07 concrete collar engr dwg pipe 08 embankment over pipes engr dwg pipe 09 pipe endwall engr dwg pipe 10 pipe headwall engr dwg pipe 11 chain link fence engr dwg | connection | standard version detail engineering version cad file conn 01 concrete cut off wall engr dwg conn 02 intentionally left blank conn 03 saddle connection engr dwg conn 04 modified saddle connection to circular sewers engr dwg conn 05 modified saddle connection to egg shaped sewers engr dwg conn 06 doghouse manhole connection to circular sewers engr dwg conn 07 doghouse manhole connection to egg shaped sewers engr dwg conn 08 combined system vent connection engr dwg | manhole | standard version detail engineering version cad file mh 01 precast concrete manhole riser cone engr dwg mh 02 concrete manhole base pipe 30 combined engr dwg mh 03 doghouse manhole pipe 30 engr dwg mh 04 precast concrete manhole bases pipe 30 engr dwg mh 05 concrete manhole base pipe 36 combined engr dwg mh 06 concrete manhole base pipe 30 seperate engr dwg mh 07 concrete manhole base pipe 36 separate engr dwg mh 08 concrete manhole base junction manhole engr dwg mh 09 summit manhole engr dwg mh 10 precast concrete drop manhole engr dwg mh 11 a precast concrete interior drop manhole pg 1 engr dwg mh 11 b precast concrete interior drop manhole pg 2 engr dwg mh 11 c precast concrete interior drop manhole pg 3 engr dwg mh 12 a wellhole pg 1 engr dwg mh 12 b wellhole pg 2 engr dwg mh 13 a gray iron manhole frame covers pg 1 engr dwg mh 13 b gray iron manhole frame covers pg 2 engr dwg mh 14 manhole steps engr dwg | inlet | standard version detail engineering version cad file inlet 01 assembly of precast inlets engr dwg inlet 02 open mouth grate inlet assembly engr dwg inlet 03 highway grate inlet assembly engr dwg inlet 04 gutter grate inlet assembly engr dwg inlet 05 open mouth inlet assembly engr dwg inlet 06 a inlet and trap installation pg 1 engr dwg inlet 06 b inlet and trap installation pg 2 engr dwg inlet 07 two piece precast catch basin engr dwg inlet 08 inlet trap engr dwg inlet 09 precast concrete reinforced inlet hood engr dwg inlet 10 highway grate and gutter grate inlet adjustment risers engr dwg inlet 11 inlet frames engr dwg inlet 12 inlet grates engr dwg inlet 13 concrete apron at open mouth grate inlet engr dwg inlet 14 open mouth inlet adjustment risers engr dwg inlet 15 precast concrete top slabs engr dwg inlet 16 top slab clean out cover frame engr dwg inlet 17 concrete apron at open mouth inlet engr dwg | specifications | standard version specification engineering version d 1 d 1 general engr d 2 d 2 standard details engr d 3 d 3 abbreviations and definitions engr d 4 d 4 requirements tests and inspections engr d 5 d 5 lines and grades engr d 6 d 6 width of trenches engr d 7 d 7 installation of pipes engr d 8 d 8 protection of pipes engr d 9 d 9 length of pipes engr d 10 d 10 provisions for lateral connections engr d 11 d 11 measurement for payment engr d 12 d 12 filling abandoned sewers engr d 13 d 13 filling abandoned manholes engr d 14 d 14 filling abandoned inlets engr d 15 d 15 vitrified clay pipe engr d 16 d 16 reinforced concrete pipe engr d 17 d 17 cast in place reinforced concrete concrete sewers stormwater conduits and special sections engr d 18 d 18 precast reinforced concrete sewers and stormwater conduits engr d 19 d 19 ductile iron pipe engr d 20 d 20 cast iron soil pipe engr d 21 d 21 manholes engr d 22 d 22 wellholes engr d 23 d 23 inlets engr d 24 d 24 chain link fence engr strd standard codes and other references in the standard specs engr","pwd_rlv_wordcount":"639"},"section":[],"class_list":["post-19","page","type-page","status-publish","hentry","wpautop"],"acf":[],"parsely":{"version":"1.1.0","canonical_url":"https:\/\/phila.gov\/design\/sewer-standard-details\/","smart_links":{"inbound":0,"outbound":0},"traffic_boost_suggestions_count":0,"meta":{"@context":"https:\/\/schema.org","@type":"WebPage","headline":"Sewer Standard Details and Specifications","url":"http:\/\/water.phila.gov\/design\/sewer-standard-details\/","mainEntityOfPage":{"@type":"WebPage","@id":"http:\/\/water.phila.gov\/design\/sewer-standard-details\/"},"thumbnailUrl":"","image":{"@type":"ImageObject","url":""},"articleSection":"Uncategorized","author":[{"@type":"Person","name":"Justin Martin"}],"creator":["Justin Martin"],"publisher":{"@type":"Organization","name":"Water &amp; Sewer Design","logo":""},"keywords":[],"dateCreated":"2021-05-07T00:12:52Z","datePublished":"2021-05-07T00:12:52Z","dateModified":"2022-10-19T00:05:34Z"},"rendered":"<script type=\"application\/ld+json\" class=\"wp-parsely-metadata\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@type\":\"WebPage\",\"headline\":\"Sewer Standard Details and Specifications\",\"url\":\"http:\\\/\\\/water.phila.gov\\\/design\\\/sewer-standard-details\\\/\",\"mainEntityOfPage\":{\"@type\":\"WebPage\",\"@id\":\"http:\\\/\\\/water.phila.gov\\\/design\\\/sewer-standard-details\\\/\"},\"thumbnailUrl\":\"\",\"image\":{\"@type\":\"ImageObject\",\"url\":\"\"},\"articleSection\":\"Uncategorized\",\"author\":[{\"@type\":\"Person\",\"name\":\"Justin Martin\"}],\"creator\":[\"Justin Martin\"],\"publisher\":{\"@type\":\"Organization\",\"name\":\"Water &amp; Sewer Design\",\"logo\":\"\"},\"keywords\":[],\"dateCreated\":\"2021-05-07T00:12:52Z\",\"datePublished\":\"2021-05-07T00:12:52Z\",\"dateModified\":\"2022-10-19T00:05:34Z\"}<\/script>","tracker_url":"https:\/\/cdn.parsely.com\/keys\/phila.gov\/p.js"},"_links":{"self":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages\/19","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/users\/26"}],"replies":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/comments?post=19"}],"version-history":[{"count":0,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/pages\/19\/revisions"}],"wp:attachment":[{"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/media?parent=19"}],"wp:term":[{"taxonomy":"section","embeddable":true,"href":"https:\/\/water.phila.gov\/design\/wp-json\/wp\/v2\/section?post=19"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}