{"id":906,"date":"2023-02-22T17:50:56","date_gmt":"2023-02-22T22:50:56","guid":{"rendered":"http:\/\/core.loc\/development\/?page_id=248"},"modified":"2023-11-17T23:33:44","modified_gmt":"2023-11-18T04:33:44","slug":"table-e-2-existing-conditions-plan-requirements","status":"publish","type":"page","link":"https:\/\/water.phila.gov\/development\/stormwater-plan-review\/manual\/appendices\/e-plan-and-report-checklists\/table-e-2-existing-conditions-plan-requirements\/","title":{"rendered":"Table E-2: Existing Conditions Plan Requirements"},"content":{"rendered":"\n<figure class=\"wp-block-flexible-table-block-table\"><table class=\"\"><thead><tr><th style=\"text-align:center\">#<\/th><th>Requirement<\/th><\/tr><\/thead><tbody><tr><td style=\"text-align:center;vertical-align:top\">1<\/td><td>General plan presentation requirements listed in Table&nbsp;E\u20111<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">2<\/td><td>Name of owner and designer<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">3<\/td><td>Site address (must match current Philadelphia Office of Property Assessment (OPA) records)<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">4<\/td><td>Location map including site location within watershed(s)<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">5<\/td><td>Property lines, all metes, bounds, boundaries, dimensions, building lines, and setbacks (must match current OPA records)<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">6<\/td><td>Street lines, street names, lot names, easements, other land divisions, and their purposes and confirmed locations<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">7<\/td><td>Location and boundaries of all existing rights-of-way, easements, cartway widths for all streets and private roads, and drainage rights-of-way<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">8<\/td><td>Location and size of all existing site features and impervious areas within 25 feet of the proposed earth disturbance even if those features are on an adjacent property<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">9<\/td><td>Location of all existing active and abandoned utilities (water, sewer, stormwater), including stormwater management practices above and below ground within 25 feet of the limit of disturbance<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">10<\/td><td>Identification of the nearest watercourses\/water bodies (within 100 feet)<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">11<\/td><td>Existing topography of site (contours, sub-basins, etc.) in one-foot contour intervals (minimum) on-site and on adjacent lands within 25 feet of the property line and on the full width of abutting public lands, and private rights-of-way and easement(s)<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">12<\/td><td>Identification of any special features of the site (natural depressions, natural berms, flood plains, etc.)<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">13<\/td><td>Identification of the type and extent of vegetation, and the location and species identification of any trees that measure greater than six inches diameter at breast height<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">14<\/td><td>Location and boundaries of proposed demolition, including all structures and pavement to be removed and all utilities to be capped or plugged<\/td><\/tr><tr><td style=\"text-align:center;vertical-align:top\">15<\/td><td>Location of any existing on-site disposal systems (septic tanks) and drain fields<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":897,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"page-manual.php","meta":{"custom_css":"","custom_js":"","dp_submitted":"0","dp_notify":"0","dp_created":"","version":"","effective":"","short-page-title":"","pwd_rlv_phrase_match":"table e 2 existing conditions plan requirements | table e 2 existing conditions plan requirements | requirement 1 general plan presentation requirements listed in table e 1 2 name of owner and designer 3 site address must match current philadelphia office of property assessment opa records 4 location map including site location within watershed s 5 property lines all metes bounds boundaries dimensions building lines and setbacks must match current opa records 6 street lines street names lot names easements other land divisions and their purposes and confirmed locations 7 location and boundaries of all existing rights of way easements cartway widths for all streets and private roads and drainage rights of way 8 location and size of all existing site features and impervious areas within 25 feet of the proposed earth disturbance even if those features are on an adjacent property 9 location of all existing active and abandoned utilities water sewer stormwater including stormwater management practices above and below ground within 25 feet of the limit of disturbance 10 identification of the nearest watercourses water bodies within 100 feet 11 existing topography of site contours sub basins etc in one foot contour intervals minimum on site and on adjacent lands within 25 feet of the property line and on the full width of abutting public lands and private rights of way and easement s 12 identification of any special features of the site natural depressions natural berms flood plains etc 13 identification of the type and extent of vegetation and the location and species identification of any trees that measure greater than six inches diameter at breast height 14 location and boundaries of proposed demolition including all structures and pavement to be removed and all utilities to be capped or plugged 15 location of any existing on site disposal systems septic tanks and drain fields","pwd_rlv_wordcount":"271"},"section":[],"class_list":["post-906","page","type-page","status-publish","hentry","wpautop"],"acf":[],"parsely":{"version":"1.1.0","canonical_url":"https:\/\/phila.gov\/development\/stormwater-plan-review\/manual\/appendices\/e-plan-and-report-checklists\/table-e-2-existing-conditions-plan-requirements\/","smart_links":{"inbound":0,"outbound":0},"traffic_boost_suggestions_count":0,"meta":{"@context":"https:\/\/schema.org","@type":"WebPage","headline":"Table E-2: Existing Conditions Plan Requirements","url":"http:\/\/water.phila.gov\/development\/stormwater-plan-review\/manual\/appendices\/e-plan-and-report-checklists\/table-e-2-existing-conditions-plan-requirements\/","mainEntityOfPage":{"@type":"WebPage","@id":"http:\/\/water.phila.gov\/development\/stormwater-plan-review\/manual\/appendices\/e-plan-and-report-checklists\/table-e-2-existing-conditions-plan-requirements\/"},"thumbnailUrl":"","image":{"@type":"ImageObject","url":""},"articleSection":"Uncategorized","author":[{"@type":"Person","name":"Lauren Sell"}],"creator":["Lauren Sell"],"publisher":{"@type":"Organization","name":"Development Services","logo":""},"keywords":[],"dateCreated":"2023-02-22T22:50:56Z","datePublished":"2023-02-22T22:50:56Z","dateModified":"2023-11-18T04:33:44Z"},"rendered":"<script type=\"application\/ld+json\" class=\"wp-parsely-metadata\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@type\":\"WebPage\",\"headline\":\"Table E-2: Existing Conditions Plan Requirements\",\"url\":\"http:\\\/\\\/water.phila.gov\\\/development\\\/stormwater-plan-review\\\/manual\\\/appendices\\\/e-plan-and-report-checklists\\\/table-e-2-existing-conditions-plan-requirements\\\/\",\"mainEntityOfPage\":{\"@type\":\"WebPage\",\"@id\":\"http:\\\/\\\/water.phila.gov\\\/development\\\/stormwater-plan-review\\\/manual\\\/appendices\\\/e-plan-and-report-checklists\\\/table-e-2-existing-conditions-plan-requirements\\\/\"},\"thumbnailUrl\":\"\",\"image\":{\"@type\":\"ImageObject\",\"url\":\"\"},\"articleSection\":\"Uncategorized\",\"author\":[{\"@type\":\"Person\",\"name\":\"Lauren Sell\"}],\"creator\":[\"Lauren Sell\"],\"publisher\":{\"@type\":\"Organization\",\"name\":\"Development Services\",\"logo\":\"\"},\"keywords\":[],\"dateCreated\":\"2023-02-22T22:50:56Z\",\"datePublished\":\"2023-02-22T22:50:56Z\",\"dateModified\":\"2023-11-18T04:33:44Z\"}<\/script>","tracker_url":"https:\/\/cdn.parsely.com\/keys\/phila.gov\/p.js"},"_links":{"self":[{"href":"https:\/\/water.phila.gov\/development\/wp-json\/wp\/v2\/pages\/906","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/water.phila.gov\/development\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/water.phila.gov\/development\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/development\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/development\/wp-json\/wp\/v2\/comments?post=906"}],"version-history":[{"count":0,"href":"https:\/\/water.phila.gov\/development\/wp-json\/wp\/v2\/pages\/906\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/development\/wp-json\/wp\/v2\/pages\/897"}],"wp:attachment":[{"href":"https:\/\/water.phila.gov\/development\/wp-json\/wp\/v2\/media?parent=906"}],"wp:term":[{"taxonomy":"section","embeddable":true,"href":"https:\/\/water.phila.gov\/development\/wp-json\/wp\/v2\/section?post=906"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}