{"id":2118,"date":"2021-06-12T17:48:18","date_gmt":"2021-06-12T21:48:18","guid":{"rendered":"https:\/\/water.phila.gov\/?page_id=2118"},"modified":"2026-02-23T17:11:23","modified_gmt":"2026-02-23T22:11:23","slug":"tree-trench","status":"publish","type":"page","link":"https:\/\/water.phila.gov\/gsi\/tools\/tree-trench\/","title":{"rendered":"Tree Trenches"},"content":{"rendered":"\n<p class=\"has-md-font-size\">A tree trench is a system of trees that are connected by an underground infiltration structure. On the surface, it looks like a row of ordinary street tree pits, but underground there is a system to manage incoming runoff.<\/p>\n\n\n\n<!--more-->\n\n\n<div class=\"wp-block-image col-12 col-sm-6\">\n<figure class=\"alignright size-large\"><img decoding=\"async\" src=\"https:\/\/water.phila.gov\/wp-content\/uploads\/images\/dsc0944.jpg\" alt=\"\" class=\"wp-image-1197\" style=\"object-fit:cover\"\/><figcaption class=\"wp-element-caption\">A stormwater tree trench separates the sidewalk from the Benjamin Franklin Parkway<\/figcaption><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-buttons type-tags noicons is-horizontal is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-7e5fce0a wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-small\"><a class=\"wp-block-button__link has-green-background-color has-background wp-element-button\" href=\"https:\/\/water.phila.gov\/projects\" target=\"_blank\" rel=\"noreferrer noopener\">Public Projects<\/a><\/div>\n<\/div>\n\n\n\n<p>A stormwater tree trench is a system of trees connected by an underground infiltration structure. On the surface, a stormwater tree trench appears like a series of street tree pits. However, under the sidewalk, there is an engineered system to manage the incoming runoff. This system is composed of a trench dug along the sidewalk, lined with a permeable geotextile fabric, filled with stone or gravel, and topped off with soil and trees. Stormwater runoff flows through a special inlet leading to the stormwater tree trench. The runoff is stored in the empty spaces between the stones, watering the trees and infiltrating through the bottom. If the capacity of this system is exceeded, stormwater runoff can bypass it entirely and flow into an existing street inlet.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity clear\"\/>\n\n\n<div class=\"wp-block-image is-style-frame\">\n<figure class=\"aligncenter size-large\"><a href=\"https:\/\/water.phila.gov\/wp-content\/uploads\/images\/tree-trench-diagram.jpg\"><img decoding=\"async\" src=\"https:\/\/water.phila.gov\/wp-content\/uploads\/images\/tree-trench-diagram.png\" alt=\"\"\/><\/a><figcaption class=\"wp-element-caption\">Diagram of a stormwater tree trench<\/figcaption><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>A tree trench is a system of trees that are connected by an underground infiltration structure. On the surface, it looks like a row of ordinary street tree pits, but underground there is a system to manage incoming runoff.<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":2104,"menu_order":70,"comment_status":"closed","ping_status":"closed","template":"","meta":{"custom_css":".type-tags .wp-block-button { display: inline-block; font-size: .85em; text-transform: lowercase; font-variant: small-caps; }\r\n.type-tags .has-purple-background-color { background: #B93F8E !important; }\r\n.type-tags .has-green-background-color { background: #3a833c !important; }\r\n.type-tags .has-black-background-color { background: #0d1a2e !important; background: #05b4e6 !important; }","dp_submitted":"0","dp_notify":"0","dp_created":"","custom_js":"var utility = document.getElementById(\"menu-item-2213\");\r\nutility.classList.add(\"current-menu-ancestor\");\r\nvar sw = document.getElementById(\"menu-item-2511\");\r\nsw.classList.add(\"current-menu-ancestor\");","noindex":""},"section":[],"class_list":["post-2118","page","type-page","status-publish","hentry","wpautop"],"acf":[],"parsely":{"version":"1.1.0","canonical_url":"https:\/\/phila.gov\/gsi\/tools\/tree-trench\/","smart_links":{"inbound":0,"outbound":0},"traffic_boost_suggestions_count":0,"meta":{"@context":"https:\/\/schema.org","@type":"WebPage","headline":"Tree Trenches","url":"http:\/\/water.phila.gov\/gsi\/tools\/tree-trench\/","mainEntityOfPage":{"@type":"WebPage","@id":"http:\/\/water.phila.gov\/gsi\/tools\/tree-trench\/"},"thumbnailUrl":"","image":{"@type":"ImageObject","url":""},"articleSection":"Uncategorized","author":[{"@type":"Person","name":"Lauren Sell"}],"creator":["Lauren Sell"],"publisher":{"@type":"Organization","name":"Green Stormwater Infrastructure","logo":""},"keywords":[],"dateCreated":"2021-06-12T21:48:18Z","datePublished":"2021-06-12T21:48:18Z","dateModified":"2026-02-23T22:11:23Z"},"rendered":"<script type=\"application\/ld+json\" class=\"wp-parsely-metadata\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@type\":\"WebPage\",\"headline\":\"Tree Trenches\",\"url\":\"http:\\\/\\\/water.phila.gov\\\/gsi\\\/tools\\\/tree-trench\\\/\",\"mainEntityOfPage\":{\"@type\":\"WebPage\",\"@id\":\"http:\\\/\\\/water.phila.gov\\\/gsi\\\/tools\\\/tree-trench\\\/\"},\"thumbnailUrl\":\"\",\"image\":{\"@type\":\"ImageObject\",\"url\":\"\"},\"articleSection\":\"Uncategorized\",\"author\":[{\"@type\":\"Person\",\"name\":\"Lauren Sell\"}],\"creator\":[\"Lauren Sell\"],\"publisher\":{\"@type\":\"Organization\",\"name\":\"Green Stormwater Infrastructure\",\"logo\":\"\"},\"keywords\":[],\"dateCreated\":\"2021-06-12T21:48:18Z\",\"datePublished\":\"2021-06-12T21:48:18Z\",\"dateModified\":\"2026-02-23T22:11:23Z\"}<\/script>","tracker_url":"https:\/\/cdn.parsely.com\/keys\/phila.gov\/p.js"},"_links":{"self":[{"href":"https:\/\/water.phila.gov\/gsi\/wp-json\/wp\/v2\/pages\/2118","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/water.phila.gov\/gsi\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/water.phila.gov\/gsi\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/gsi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/gsi\/wp-json\/wp\/v2\/comments?post=2118"}],"version-history":[{"count":1,"href":"https:\/\/water.phila.gov\/gsi\/wp-json\/wp\/v2\/pages\/2118\/revisions"}],"predecessor-version":[{"id":2894,"href":"https:\/\/water.phila.gov\/gsi\/wp-json\/wp\/v2\/pages\/2118\/revisions\/2894"}],"up":[{"embeddable":true,"href":"https:\/\/water.phila.gov\/gsi\/wp-json\/wp\/v2\/pages\/2104"}],"wp:attachment":[{"href":"https:\/\/water.phila.gov\/gsi\/wp-json\/wp\/v2\/media?parent=2118"}],"wp:term":[{"taxonomy":"section","embeddable":true,"href":"https:\/\/water.phila.gov\/gsi\/wp-json\/wp\/v2\/section?post=2118"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}